SS 2 · Chemistry
Rates of reaction: disappearing cross and marble chips
Practical code SL-S2-X09
Aim: To find how concentration, temperature and surface area affect the rate of a reaction, using the disappearing cross and the loss of mass of marble in acid.
Apparatus
- Conical flask, paper marked with a black cross
- Stop-clock
- Measuring cylinders
- 40 g/dm³ sodium trioxothiosulphate(VI) (sodium thiosulphate) and 2.0 mol/dm³ HCl
- Thermometer and water bath
- Top-pan balance, cotton wool, marble chips and marble powder
Method
- Make up 50 cm³ of thiosulphate solution with water (50, 40, 30, 20 and 10 cm³ of the stock). Stand the flask on the cross.
- Add 5 cm³ of the acid, start the clock and swirl. Stop the clock when the cross can no longer be seen from above. Work out 1/t.
- Repeat with 20 cm³ of thiosulphate and 30 cm³ of water warmed to 30, 40, 50 and 60 °C.
- Put marble chips in excess in 50 cm³ of 2.0 mol/dm³ HCl on a balance, with cotton wool in the neck. Record the mass every 60 s for 420 s. Repeat with the same mass of powder.
- Plot mass lost against time for chips and powder on the same axes. Draw a tangent at t = 0 to find each initial rate.
Safety: In a real laboratory, the thiosulphate reaction gives off sulphur(IV) oxide: work in a well-ventilated room and pour the mixture away promptly. Wear eye protection with acid, and do not heat the thiosulphate above 60 °C.