SS 1 · Biology
Enzyme activity: temperature and pH
Practical code SL-S1-X04
Aim: To find the optimum temperature for catalase (in liver or potato) and the optimum pH for salivary amylase.
Apparatus
- Test tubes and a rack
- Water baths at 10 °C to 70 °C and a thermometer
- Hydrogen peroxide solution (dilute)
- Fresh liver and raw potato, and a boiled sample as a control
- Amylase solution and 1% starch solution
- Buffer solutions of pH 3 to 9
- A spotting tile with iodine solution and a dropper
- A ruler and a stopwatch
Method
- Catalase: put 5 cm³ of hydrogen peroxide in a tube and stand it in a water bath until it reaches the chosen temperature.
- Add a 1 cm³ cube of liver (or potato) and measure the height of the foam after 2 minutes.
- Repeat at each temperature, and with boiled liver as a control.
- Amylase: mix 2 cm³ of buffer, 2 cm³ of starch and 1 cm³ of amylase at 37 °C and start the stopwatch.
- Every 30 s, put one drop of the mixture onto iodine on the spotting tile. Note the time when the spot first stays yellow-brown.
- Work out the rate as 1 / time and plot both graphs.
Safety: In a real laboratory, wear eye protection because hydrogen peroxide irritates the eyes and skin, wash your hands after handling raw liver, and do not taste or drink anything, including saliva or starch mixtures.