SS 2 · Physics
E.m.f. and internal resistance of a cell
Practical code SL-S2-X13
Aim: To find the e.m.f. E and internal resistance r of a dry cell from a graph of terminal p.d. V against current I (V = E − Ir).
Apparatus
- A part-used 1.5 V dry cell
- A key
- A rheostat (or, in the WAEC variant, a resistance box)
- An ammeter (0–1 A)
- A high-resistance voltmeter (0–3 V)
- Connecting wires
Method
- With the key open, read the voltmeter across the cell. On open circuit it reads (almost) the e.m.f.
- Close the key and adjust the rheostat until the ammeter reads 0.10 A. Read the voltmeter, then open the key at once.
- Repeat for I = 0.20, 0.30, 0.40, 0.50 and 0.60 A, opening the key between readings.
- Plot V against I. The intercept on the V-axis is E and the gradient is −r.
- WAEC variant: use a resistance box R and the ammeter only. Record I for R = 1 to 6 Ω, plot 1/I against R: gradient = 1/E and intercept = r/E.
Safety: In a real laboratory, never join the cell's terminals directly with a wire (a short circuit makes it hot), and open the key between readings. Use cells only, never the mains.
This practical is part of Science Lab